DATE | HS_CODE | Product Description | Trademark | Country | Net Weight | Statistical Cost | Place | Shipper Name | Consignee Name |
---|
2017-09-22 | 9032890000 | Instruments and apparatus for Automatic regulating or controlling: UNIVERSAL CONTROLLER (CONTROLLER) to control the temperature, humidity, pressure, flow and air quality in the air-conditioning system, 1 loop controls, 24V, TIP.RLU UNI. | *** | SWITZERLAND | 1.7 | 399,97 | *** | ***** | ***** |
2017-09-22 | 9025198009 | Thermometers not incorporated with other devices: TEMPERATURE SENSOR CHANNEL, FLEXIBLE The sensing element LG-NI 1000 Installation length 400mm, 24V SENSOR OUTDOOR CONTROL SYSTEMS HVAC AIR | *** | SWITZERLAND | 42.89 | 6358,72 | *** | ***** | ***** |
2017-09-22 | 9025808000 | MEASURING MOISTURE AND AIR TEMPERATURE: ROOM SENSOR CONDITIONING FOR SUBSYSTEMS, APPLICATION 15: +50 ° C / 0:95% rel. Wet., Pete. AC 24 V, DC 13.5-35 V TYPE QFA room sensor for subsystems AIR CONDITIONING RANGE | *** | SWITZERLAND | 1.56 | 1064,36 | *** | ***** | ***** |
2017-10-02 | 9026202000 | MEASURING AND PRESSURE CONTROL, ELECTRONIC - PART FOR VENTILATION AND AIR CONDITIONING IN INDUSTRIAL AREAS ARE FREE sources of ionizing radiation: Pressure sensors for the measurement and control VOHZDUHA PRESSURE TO THE SYSTEM | *** | SWITZERLAND | 11 | 1046,66 | *** | ***** | ***** |
2017-10-06 | 9025804000 | Devices operating when immersed LIQUID ELECTRONIC: ROOM HUMIDITY SENSOR FOR NRC steam humidifiers AT4, DC4 for measuring the humidity in the ventilation system duct sensor HUMIDITY the NDC, is used to measure the humidity in AIR AND KANALAH.DLYA | *** | SWITZERLAND | 21 | 698,56 | *** | ***** | ***** |
2017-10-11 | 9026202000 | MEASURING AND PRESSURE CONTROL, ELECTRONIC - PART FOR VENTILATION AND AIR CONDITIONING IN INDUSTRIAL AREAS ARE FREE sources of ionizing radiation: Pressure sensors for the measurement and control VOHZDUHA PRESSURE TO THE SYSTEM | *** | SWITZERLAND | 1.2 | 113,92 | *** | ***** | ***** |
2017-10-11 | 9026208000 | Pressure gauges with capsule element, for air SYSTEM LOW PRESSURE EXPANSION NODE acetate tow, tobacco EQUIPMENT FOR OWN NEEDS ARE FREE OF RADIOACTIVE SOURCES AND RADIATION ARE FREE AND RES WIKA HFD without the goods | *** | SWITZERLAND | 0.18 | 80,21 | *** | ***** | ***** |
2017-10-13 | 9025808000 | MEASURING MOISTURE AND AIR TEMPERATURE: ROOM SENSOR CONDITIONING FOR SUBSYSTEMS, APPLICATION 15: +50 ° C / 0:95% rel. Wet. PETE. AC 24 V, DC 13.5-35 In, QFA TYPE ART.QFA2060-1SHT room sensors are conditioned for subsystems | *** | SWITZERLAND | 0.28 | 183,03 | *** | ***** | ***** |
2017-10-13 | 9027809900 | ELECTRONIC DEVICES FOR AIR QUALITY ANALYSIS (NOT SODER.ISTOCHNIKOV IONIZIRUESCHEGO RADIATION): PROBE FOR DETERMINATION OF CO2 concentration in the air in air conditioning systems, the operating voltage AC 24 V, DC 15.35 V, ART.QPM2100-4SHT sensor for determining K | *** | SWITZERLAND | 1.01 | 747,54 | *** | ***** | ***** |
2017-10-13 | 9032102000 | THERMOSTATS ELECTRONIC WIRED FOR SYSTEMS AVT.UPRAVLENIYA water floor, wall and ceiling heating / cooling, * NOT APPLY TO RADIO and high frequency devices UPONOR SMATRIX BASE THERMOSTAT PUBLIC T-143 measures the temperature AIR BUS | *** | SWITZERLAND | 9.08 | 1345,54 | *** | ***** | ***** |